Model: XW-5V30A128CH
Max votage: 5V
Max current: 30A
Channels: 128
Cell: 32130/33140
Usage: for cylindrcial cell charge and discharge capacity grading
Type: Energy regenerative
Certification: CE
MOQ: 1 pcs
Leading time: 10-15 days
Warranty: 1 year

Please enable JavaScript in your browser to complete this form.

Description

The Battery Grading Machine is mainly used for formation and capacity grading of cylindrical lithium ion batteries.
Formation is first small current charging of a newly built lithium ion battery, aimed at forming a passivation layer on the surface of the negative electrode, that is, the solid electrolyte boundary film (SEI film).
Capacity grading means test the capacity of the cell via charge and discharge process, and grading the cells according the capacity value. This is for balance the battery pack assembling.
Battery Grading Machine is mainly composed of computer system, control software, communication interface and battery detection cabinet. The battery detection cabinet is composed of a clamp and a board body for placing the clamp, a charging constant current and voltage source, a discharging constant current source, a storage control circuit, a current sampling circuit, a voltage sampling circuit, a main control CPU, a data memory, a single-chip microcomputer program and a control panel.

Parameters
Equipment structure
Number of equipment channels 128 channels
Size 1620LmmxW950mmx1840Hmm
Fixture form four-wire method fixture
Fixture distance 37mm
Support cell model 32130, 33140
Working power 3-phase five-wire AC380V ± 10%, 50HZ
Working power ≤27KW
Working environment temperature 0 ~ 40 ℃, relative humidity ≤80%
Cooling method natural air intake, upward exhaust
Channel parameters
Voltage measurement range 0-5V, resolution 1mV
Battery voltage range charging 0-4.5V;discharging 4.5-2V
Constant voltage range 2.5-4.5V
Voltage accuracy ±(1 ‰ reading + 1 ‰ full scale)
Current range charge 100mA -30A; discharge 100mA -30A, resolution 1mA
Current accuracy ±(1 ‰ reading + 1 ‰ full scale)
Type Energy regenerative, save energy
Feedback efficiency >70%
Software functions
Control mode software installed computer connected equipment work, whole cabinet control
Communication method RS485, baud rate 57600
Process setting up to 32 steps and 256 cycles can be set
Charging mode constant current, constant voltage
Charging cut-off conditions voltage, current, time, capacity
Discharge mode constant current
Discharge cut-off conditions voltage, time, capacity
Protection function over voltage, under voltage, over current, under current, over capacity protection, power failure protection, data breakpoint recovery
Time range arbitrarily set within 0-30000 minutes, time unit is min
Time accuracy ≤±1 ‰
Sampling inspection cycle ≤8s
Minimum data recording frequency ≤8s
Battery sorting sort by (capacity, time, open circuit voltage, discharge platform, etc.)
Data processing can record voltage, current, time, capacity and other data, automatically calculate constant current charge ratio, capacity loss, discharge efficiency, average voltage, median voltage and other data, provide data graph sand cycle diagrams; can generate text, EXCEL, WORD or MDB database format file