XW-5V30A128CH Cell Grading Machine for 32130/33140 Cylindrical Battery
- Home
- Cylindrical battery pack machine
- Cylindrical cell grading machine
- XW-5V30A128CH Cell Grading Machine for 32130/33140 Cylindrical Battery
Model: XW-5V30A128CH
Max votage: 5V
Max current: 30A
Channels: 128
Cell: 32130/33140
Usage: for cylindrcial cell charge and discharge capacity grading
Type: Energy regenerative
Certification: CE
MOQ: 1 pcs
Leading time: 10-15 days
Warranty: 1 year
- Description
- Parameters
- Video
The Battery Grading Machine is mainly used for formation and capacity grading of cylindrical lithium ion batteries.
Formation is first small current charging of a newly built lithium ion battery, aimed at forming a passivation layer on the surface of the negative electrode, that is, the solid electrolyte boundary film (SEI film).
Capacity grading means test the capacity of the cell via charge and discharge process, and grading the cells according the capacity value. This is for balance the battery pack assembling.
Battery Grading Machine is mainly composed of computer system, control software, communication interface and battery detection cabinet. The battery detection cabinet is composed of a clamp and a board body for placing the clamp, a charging constant current and voltage source, a discharging constant current source, a storage control circuit, a current sampling circuit, a voltage sampling circuit, a main control CPU, a data memory, a single-chip microcomputer program and a control panel.
Equipment structure | |
Number of equipment channels | 128 channels |
Size | 1620LmmxW950mmx1840Hmm |
Fixture form | four-wire method fixture |
Fixture distance | 37mm |
Support cell model | 32130, 33140 |
Working power | 3-phase five-wire AC380V ± 10%, 50HZ |
Working power | ≤27KW |
Working environment | temperature 0 ~ 40 ℃, relative humidity ≤80% |
Cooling method | natural air intake, upward exhaust |
Channel parameters | |
Voltage measurement range | 0-5V, resolution 1mV |
Battery voltage range | charging 0-4.5V;discharging 4.5-2V |
Constant voltage range | 2.5-4.5V |
Voltage accuracy | ±(1 ‰ reading + 1 ‰ full scale) |
Current range | charge 100mA -30A; discharge 100mA -30A, resolution 1mA |
Current accuracy | ±(1 ‰ reading + 1 ‰ full scale) |
Type | Energy regenerative, save energy |
Feedback efficiency | >70% |
Software functions | |
Control mode | software installed computer connected equipment work, whole cabinet control |
Communication method | RS485, baud rate 57600 |
Process setting | up to 32 steps and 256 cycles can be set |
Charging mode | constant current, constant voltage |
Charging cut-off conditions | voltage, current, time, capacity |
Discharge mode | constant current |
Discharge cut-off conditions | voltage, time, capacity |
Protection function | over voltage, under voltage, over current, under current, over capacity protection, power failure protection, data breakpoint recovery |
Time range | arbitrarily set within 0-30000 minutes, time unit is min |
Time accuracy | ≤±1 ‰ |
Sampling inspection cycle | ≤8s |
Minimum data recording frequency | ≤8s |
Battery sorting | sort by (capacity, time, open circuit voltage, discharge platform, etc.) |
Data processing | can record voltage, current, time, capacity and other data, automatically calculate constant current charge ratio, capacity loss, discharge efficiency, average voltage, median voltage and other data, provide data graph sand cycle diagrams; can generate text, EXCEL, WORD or MDB database format file |