XW-100V50A Battery Pack Charge and Discharge Aging Cycle Machine

Model: XW-100V50A
Voltage: 100V
Current: 50A
Channel: customized
Type: Energy regenerative
Usage: battery pack charge discharge aging and capacity testing
Warranty: 1 year

SKU: XW-100V50AXCH Category:
General Details

XW-100V50A Battery Pack Charge and Discharge Aging Cycle Machine is used for lithium battery pack charge-discharge cycle testing, aging treatment, capacity verification and shipment quality control. It simulates real charging and discharging conditions and records voltage, current, capacity and cycle data during battery pack testing.

This model is designed for 100V battery packs with 50A current. It is suitable for energy storage packs, light electric vehicle packs, power tool packs, industrial lithium battery packs and customized battery production projects.

Machine Function

  • Charge and discharge battery packs under controlled voltage and current
  • Run aging cycle tests to verify pack stability and durability
  • Measure capacity, voltage, current and cycle performance
  • Record historical test data for production traceability
  • Support data export for battery quality reports

Key Features

  • Designed for 100V 50A lithium battery pack testing
  • Energy regenerative design returns discharge energy to the power grid
  • Computer software interface for process editing and data management
  • Independent channel control for flexible battery pack testing
  • Supports constant current and constant voltage charge-discharge steps
  • Four-wire voltage and current sampling for better measurement accuracy

Applications

  • Lithium battery pack aging and capacity testing
  • Energy storage battery pack production
  • E-bike, scooter and light electric vehicle battery pack testing
  • Power tool and industrial battery pack quality control
  • Battery pack repair, maintenance and performance verification

Product Images

XW-100V50A Battery Pack Charge and Discharge Aging Cycle Machine

XW-100V50A Battery Pack Charge and Discharge Aging Cycle Machine

XW-100V50A Battery Pack Charge and Discharge Aging Cycle Machine

XW-100V50A Battery Pack Charge and Discharge Aging Cycle Machine

XW-100V50A Battery Pack Charge and Discharge Aging Cycle Machine

XW-100V50A Battery Pack Charge and Discharge Aging Cycle Machine

Information Needed for Quotation

  • Battery pack voltage range and maximum charge voltage
  • Required charge current and discharge current
  • Number of test channels
  • Battery chemistry and pack capacity range
  • Required test steps, aging time and data export format
  • Factory power supply and energy feedback requirement

FAQ

What battery packs can XW-100V50A test?

XW-100V50A is suitable for 100V battery packs that require up to 50A charge-discharge current. XWELL can also provide other voltage and current models according to your specification.

Can the channel quantity be customized?

Yes. The channel quantity can be customized according to daily testing capacity, production line layout and battery pack size.

Can the machine export test data?

Yes. The software can export cycle data, process data and detailed records for quality control and traceability.

Related Equipment

  • Battery BMS testing machine
  • Battery pack comprehensive testing machine
  • Battery pack spot welding machine
  • Battery pack assembly line

Request a Battery Pack Testing Solution

Send us your pack voltage, current range, channel quantity, battery capacity and test process. XWELL can recommend a suitable charge and discharge aging machine for your project.

Parameters
Item Parameter
Model XW-100V50AXCH
Number of channels X, customized
Maximum power 48KW
System function 1. Battery cycle life test

2. Battery capacity test

3. Battery charge/discharge characteristics test

4. Battery charge retention ability test

5. Battery charge/discharge efficiency test

6. Battery over charge/over discharge rate endurance test

AC input interface 1. Input three-phase five-wire system: AC304V~456V,50/60HZ.

2. Input current:73A; 80A-3P circuit breaker is recommended.

3. Frequency: 50Hz

4.THD≦3%

5. Power factor > 0.99 (rated power)

6. Charge efficiency: <=85%,Discharge efficiency: <=84% (the whole machine)

7. Feedback efficiency of bus: 92%

Charging voltage DC 0~100V The voltage range that can be detected and set during charging is up to 100V
Discharge voltage DC 100~8V The range of voltages that can be detected and set when discharging, with a minimum voltage of 8V
Charging current DC 0~50A The range of current that can be detected and set during charging, the maximum current is 50A
Discharge current DC 0~50A Current range that can be used to detect and set when discharging, the maximum current is 50A
Voltage accuracy ±0.05% of F.S±0.05% of F.D
Current accuracy ±0.05% of F.S±0.05% of F.D
Power accuracy ±0.05% of F.S±0.05% of F.D
Current response time Current hardware response time: ≤50ms
Time setting range 1,000 minutes/step
Voltage and current detection Four-wire connection
Data recording frequency ≥1000ms
Output DC voltage resolution 1mV
Minimum output current 50mA
Minimum discharge voltage 8V (voltage of device port)
Output DC current resolution 1mA
Channel parallel connection Support max 4 channels in parallel
Data export mode The data can be exported to EXCEL and chart files, providing a variety of data analysis curves and data lists such as charge and discharge curve, capacity attenuation rate, cycle life curve, charge and discharge voltage, current, capacity-time, etc..
Data storage mode Users can customize the file name and data saving path, with data saved in file format.
Working mode of main channel Charge: constant current (CC) charge, constant voltage (CV) charge, constant current and constant voltage (CCCV) charge.
Discharge: constant current discharge (CD), constant current and constant voltage discharge (CVD)
Communication mode LAN (TCP/IP)
BMS communication method CAN/RS485(Modbus)(Customized)
Test data recording Voltage, current, time, capacity, electric quantity
Input protection Over-voltage, over-current, open phase, over-temperature, protection alarm and islanding protection;
Output protection Over-voltage, over-current, short circuit, reverse connection, capacity, temperature, no output when the battery voltage is not detected;
Software protection Power failure data protection, power-on resume, over-voltage and over-discharge protection, over-current and under-current protection, capacity protection, over-temperature protection, abnormal protection against voltage trend, abnormal protection against current trend, abnormal protection against current fluctuation, abnormal protection against voltage fluctuation, abnormal protection against rising speed of charging voltage and abnormal protection against falling speed of discharging current;
Number of cycles Max. 10,000 times
Cooling mode Forced air cooling
Dimensions (W*D*H) 650*600*1600mm
Ambient temperature -20℃~50℃
Humidity 10-90%RH