XW-100V50A Battery Pack Charge and Discharge Aging Cycle Machine
- Home
- Battery testing equipment
- Battery charge and discharge aging machine
- XW-100V50A Battery Pack Charge and Discharge Aging Cycle Machine
Model: XW-100V50A
Voltage: 100V
Current: 50A
Channel: customized
Type: Energy regenerative
Usage: battery pack charge discharge aging and capacity testing
Warranty: 1 year
- General Details
- Parameters
XW-100V50A Battery Pack Charge and Discharge Aging Cycle Machine is used for lithium battery pack charge-discharge cycle testing, aging treatment, capacity verification and shipment quality control. It simulates real charging and discharging conditions and records voltage, current, capacity and cycle data during battery pack testing.
This model is designed for 100V battery packs with 50A current. It is suitable for energy storage packs, light electric vehicle packs, power tool packs, industrial lithium battery packs and customized battery production projects.
Machine Function
- Charge and discharge battery packs under controlled voltage and current
- Run aging cycle tests to verify pack stability and durability
- Measure capacity, voltage, current and cycle performance
- Record historical test data for production traceability
- Support data export for battery quality reports
Key Features
- Designed for 100V 50A lithium battery pack testing
- Energy regenerative design returns discharge energy to the power grid
- Computer software interface for process editing and data management
- Independent channel control for flexible battery pack testing
- Supports constant current and constant voltage charge-discharge steps
- Four-wire voltage and current sampling for better measurement accuracy
Applications
- Lithium battery pack aging and capacity testing
- Energy storage battery pack production
- E-bike, scooter and light electric vehicle battery pack testing
- Power tool and industrial battery pack quality control
- Battery pack repair, maintenance and performance verification
Product Images






Information Needed for Quotation
- Battery pack voltage range and maximum charge voltage
- Required charge current and discharge current
- Number of test channels
- Battery chemistry and pack capacity range
- Required test steps, aging time and data export format
- Factory power supply and energy feedback requirement
FAQ
What battery packs can XW-100V50A test?
XW-100V50A is suitable for 100V battery packs that require up to 50A charge-discharge current. XWELL can also provide other voltage and current models according to your specification.
Can the channel quantity be customized?
Yes. The channel quantity can be customized according to daily testing capacity, production line layout and battery pack size.
Can the machine export test data?
Yes. The software can export cycle data, process data and detailed records for quality control and traceability.
Related Equipment
- Battery BMS testing machine
- Battery pack comprehensive testing machine
- Battery pack spot welding machine
- Battery pack assembly line
Request a Battery Pack Testing Solution
Send us your pack voltage, current range, channel quantity, battery capacity and test process. XWELL can recommend a suitable charge and discharge aging machine for your project.
| Item | Parameter |
| Model | XW-100V50AXCH |
| Number of channels | X, customized |
| Maximum power | 48KW |
| System function | 1. Battery cycle life test
2. Battery capacity test 3. Battery charge/discharge characteristics test 4. Battery charge retention ability test 5. Battery charge/discharge efficiency test 6. Battery over charge/over discharge rate endurance test |
| AC input interface | 1. Input three-phase five-wire system: AC304V~456V,50/60HZ.
2. Input current:73A; 80A-3P circuit breaker is recommended. 3. Frequency: 50Hz 4.THD≦3% 5. Power factor > 0.99 (rated power) 6. Charge efficiency: <=85%,Discharge efficiency: <=84% (the whole machine) 7. Feedback efficiency of bus: 92% |
| Charging voltage | DC 0~100V The voltage range that can be detected and set during charging is up to 100V |
| Discharge voltage | DC 100~8V The range of voltages that can be detected and set when discharging, with a minimum voltage of 8V |
| Charging current | DC 0~50A The range of current that can be detected and set during charging, the maximum current is 50A |
| Discharge current | DC 0~50A Current range that can be used to detect and set when discharging, the maximum current is 50A |
| Voltage accuracy | ±0.05% of F.S±0.05% of F.D |
| Current accuracy | ±0.05% of F.S±0.05% of F.D |
| Power accuracy | ±0.05% of F.S±0.05% of F.D |
| Current response time | Current hardware response time: ≤50ms |
| Time setting range | 1,000 minutes/step |
| Voltage and current detection | Four-wire connection |
| Data recording frequency | ≥1000ms |
| Output DC voltage resolution | 1mV |
| Minimum output current | 50mA |
| Minimum discharge voltage | 8V (voltage of device port) |
| Output DC current resolution | 1mA |
| Channel parallel connection | Support max 4 channels in parallel |
| Data export mode | The data can be exported to EXCEL and chart files, providing a variety of data analysis curves and data lists such as charge and discharge curve, capacity attenuation rate, cycle life curve, charge and discharge voltage, current, capacity-time, etc.. |
| Data storage mode | Users can customize the file name and data saving path, with data saved in file format. |
| Working mode of main channel | Charge: constant current (CC) charge, constant voltage (CV) charge, constant current and constant voltage (CCCV) charge. |
| Discharge: constant current discharge (CD), constant current and constant voltage discharge (CVD) | |
| Communication mode | LAN (TCP/IP) |
| BMS communication method | CAN/RS485(Modbus)(Customized) |
| Test data recording | Voltage, current, time, capacity, electric quantity |
| Input protection | Over-voltage, over-current, open phase, over-temperature, protection alarm and islanding protection; |
| Output protection | Over-voltage, over-current, short circuit, reverse connection, capacity, temperature, no output when the battery voltage is not detected; |
| Software protection | Power failure data protection, power-on resume, over-voltage and over-discharge protection, over-current and under-current protection, capacity protection, over-temperature protection, abnormal protection against voltage trend, abnormal protection against current trend, abnormal protection against current fluctuation, abnormal protection against voltage fluctuation, abnormal protection against rising speed of charging voltage and abnormal protection against falling speed of discharging current; |
| Number of cycles | Max. 10,000 times |
| Cooling mode | Forced air cooling |
| Dimensions (W*D*H) | 650*600*1600mm |
| Ambient temperature | -20℃~50℃ |
| Humidity | 10-90%RH |