100V 20A Charge 40A Discharge Battery Pack Charge and Discharge Aging Machine

Model: BCDS100-20-40
sage: For battery pack charge and discharge aging capacity testing
Type: 100V voltage, 20A charge, 40A discharge
Certification: CE
MOQ: 1 pcs
Leading time: 10-15 days
Warranty: 1 year

Please enable JavaScript in your browser to complete this form.

SKU: BCDS100-20-40 Category:
Description

The Battery Pack Charge and Discharge Aging Machine is mainly used for the charge and discharge cycle test of the finished lithium battery.
The test items include: battery charge protection voltage, discharge protection voltage, battery capacity, etc.; the equipment has 4 test steps of charging, discharging, shelving, and cycling. You can make the battery test in accordance with the set process.
The test functions are:
1) Battery charge protection voltage
2) Discharge protection voltage
3) Battery capacity

100V 20A Charge 40A Discharge Battery Pack Charge and Discharge Aging Machine

 

100V 20A Charge 40A Discharge Battery Pack Charge and Discharge Aging Machine Computer Software

100V 20A Charge 40A Discharge Battery Pack Charge and Discharge Aging Machine structure

Explosion-proof cabinet
Explosion-proof cabinet for storing batteries。
The cabinet is explosion-proof, it will keep safty during testing.

Computer software
The charge and discharge aging machine can connect to computer via Serial port or Net.
Computer software is multi-fuctional, can set the parameters of testing, test steps, record test data, and output test data to Excel, TXT.

1) Single channel control technology, each channel is independent of each other
2) Anti-reverse connection protection function, data is automatically saved in real time
3) Two communication methods: serial port and network
4) Data output to Excel, TXT

 

Parameters
No Item Item
1 Power supply AC220V 50Hz
2 Power 2000W
3 Test range 0-100V
4 Voltage Accuracy ±(0.2% of reading +0.2% of range)
5 Current Charge range 200-20000mA
6 Charge accuracy ±(0.2% of reading +0.2% of range)
7 Discharge range 200-40000mA
8 Discharge accuracy ±(0.2% of reading +0.2% of range)
9 Charge Constant voltage cut-off current Min 200mA
10 Capacity Accuracy ±1‰
11 Power Discharge power ≤4000w
12 Inspection time <2s
13 Time Timing range 0-999 h/steps
14 Data record interval ≥5s
15 Channels per box 1
16 Charge mode Constant current and constant voltage charging
17 Charge Cut-off condition Voltage, current, relative time, overcharge protection
18 Discharge mode Constant current discharge
19 Discharge Cut-off condition Voltage, relative time, overcharge protection
20 Cycle test range 1-999 times
21 Cycle Max steps in one cycle 100
22 Voltage current sample 4 wires
23 Database SQL
24 Communication TCP/IP, Serial port
25 Data output EXCEL, TXT
26 Size 800*520*1370mm
27 Battery cabinet size 720*400*420mm
Video