Model: BCDS100-20-40
sage: For battery pack charge and discharge aging capacity testing
Type: 100V voltage, 20A charge, 40A discharge
Certification: CE
MOQ: 1 pcs
Leading time: 10-15 days
Warranty: 1 year
- Description
- Parameters
- Video
The Battery Pack Charge and Discharge Aging Machine is mainly used for the charge and discharge cycle test of the finished lithium battery.
The test items include: battery charge protection voltage, discharge protection voltage, battery capacity, etc.; the equipment has 4 test steps of charging, discharging, shelving, and cycling. You can make the battery test in accordance with the set process.
The test functions are:
1) Battery charge protection voltage
2) Discharge protection voltage
3) Battery capacity
100V 20A Charge 40A Discharge Battery Pack Charge and Discharge Aging Machine
100V 20A Charge 40A Discharge Battery Pack Charge and Discharge Aging Machine Computer Software
100V 20A Charge 40A Discharge Battery Pack Charge and Discharge Aging Machine structure
Explosion-proof cabinet
Explosion-proof cabinet for storing batteries。
The cabinet is explosion-proof, it will keep safty during testing.Computer software
The charge and discharge aging machine can connect to computer via Serial port or Net.
Computer software is multi-fuctional, can set the parameters of testing, test steps, record test data, and output test data to Excel, TXT.
1) Single channel control technology, each channel is independent of each other
2) Anti-reverse connection protection function, data is automatically saved in real time
3) Two communication methods: serial port and network
4) Data output to Excel, TXT
No | Item | Item | |
1 | Power supply | AC220V 50Hz | |
2 | Power | 2000W | |
3 | Test range | 0-100V | |
4 | Voltage | Accuracy | ±(0.2% of reading +0.2% of range) |
5 | Current | Charge range | 200-20000mA |
6 | Charge accuracy | ±(0.2% of reading +0.2% of range) | |
7 | Discharge range | 200-40000mA | |
8 | Discharge accuracy | ±(0.2% of reading +0.2% of range) | |
9 | Charge | Constant voltage cut-off current | Min 200mA |
10 | Capacity | Accuracy | ±1‰ |
11 | Power | Discharge power | ≤4000w |
12 | Inspection time | <2s | |
13 | Time | Timing range | 0-999 h/steps |
14 | Data record interval | ≥5s | |
15 | Channels per box | 1 | |
16 | Charge mode | Constant current and constant voltage charging | |
17 | Charge | Cut-off condition | Voltage, current, relative time, overcharge protection |
18 | Discharge mode | Constant current discharge | |
19 | Discharge | Cut-off condition | Voltage, relative time, overcharge protection |
20 | Cycle test range | 1-999 times | |
21 | Cycle | Max steps in one cycle | 100 |
22 | Voltage current sample | 4 wires | |
23 | Database | SQL | |
24 | Communication | TCP/IP, Serial port | |
25 | Data output | EXCEL, TXT | |
26 | Size | 800*520*1370mm | |
27 | Battery cabinet size | 720*400*420mm |